Kidde Slick 1x 2SFW Optical Smoke & 1x 3SFW Heat Alarm Kit Mains Powered with Alkaline Battery Back-Up
Kidde Slick 1x 2SFW Optical Smoke & 1x 3SFW Heat Alarm Kit Mains Powered with Alkaline Battery Back-Up
FULLY COMPLY WITH THE NEW 2022 SCOTTISH & WELSH REGULATIONS
1x Mains Powered Optical Smoke Alarm (2SFW):
Mains Optical Smoke Alarm Features:
Mains-powered Optical smoke alarm from the ‘Slick’ range of fast-fit alarms that can be interconnected with up to 23 other Kidde and Firex mains alarms.
Optional wireless capability using Wireless Alarm Base (RF-SFTP) for wire-free interconnection.
The ‘Slick’ range requires installation by a professionally qualified electrician and complies with UK Building Regulations for new housing and associated standards (Grade D, BS5839, Part 6).
- Unique fast-fit system with separate base plate, for ease of fitting and maintenance
- Integral, double-decker screwless terminal block for fast, push-fit connection
- Auto reset after activation
- Separate Test and Hush buttons to test and temporarily silence nuisance alarms
- Alkaline back-up battery provides continuous operation in the event of mains failure
- Interconnectable with other Kidde mains smoke and heat alarms and Kidde mains CO alarms using ‘Smart Interconnect’ technology
- Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
- Wireless capability – use with optional Wireless Alarm Base (RF-SFTP) for RF interlink function
- Deep Base – allows easier wiring
Mains Optical Smoke Alarm Specification:
- Model 2SFW
- Power Supply 230V mains
- Temperature Range 0ºC to +40ºC
- Humidity Range Up to 93% Relative Humidity (RH) non-condensing
- Storage and Transport -20ºC to +60ºC and 5–95% relative humidity (RH) non-condensing
- Alarm Dimensions 135 x 135 x 60mm (including ‘Slick’ mounting base)
- Alarm Weight 280g
- Warranty 10 years
- Approvals BSI certified to BS EN14604:2005
- CE tested and certified
- Associated Standard BS 5839 Part 6 Grade D
- Sensor Optical chamber with insect-resistant width slot entry inlet portals
- Chamber Size 41mm outside diameter x 16mm approximate depth (external)
- Sensitivity Complies with BS EN14604:2005
- Detection Band infrared light wavelength
- Button Test Simulates the effect of smoke within the sensing chamber, checks electronics and sounder
- Automatic Self-test Circuitry is tested every 40 seconds and unit beeps if fault is detected
- Supply Voltage 230V AC, 50 Hz (nominal UK voltage)
- Power Consumption Maximum 80mA
- Battery Back-up User-replaceable alkaline 9V battery (MX1604)
- Battery Monitoring Battery is monitored and unit emits a single chirp every 40 seconds if a fault is present
- Low Battery Warning 30-day low battery indicator
- Power-on Indicator Continuous green LED
- Alarm Sounder Electronic piezo-electric sounder (T3 pattern sound - three pulses - space - three pulses)
- Sound Output 85dB (A) minimum at 3 metres
- Alarm Frequency 3.2 kHz typical
- Alarm Status Red LED flashes rapidly, typically once every 2/3 seconds = unit sensing a fire event
- Red LED flashes once every 10 seconds = unit in hush condition, auto reset after 7 minutes
- Red LED flashes once every 35 seconds = normal quiescent operation
- Interconnection Up to 24 units (smoke, heat and CO) can be hardwire interconnected using SMART® interconnect system with optional control (see below)
- Up to 15 units can be wireless interconnected using appropriate Wireless Base RF-SFTP
- Optional Controls Wireless Base Remote Test and Hush Unit (KN-RTH-RF) when used with Wireless Base
- Fixing ‘Slick’ mounting deep base as supplied
- Base Cable Connect. Screwless Terminal Block with slot release feature for conductors
1x Mains Powered Heat Alarm (3SFW):
Mains Heat Alarm Features:
Mains powered heat alarm from the ‘Slick’ range of fast-fit alarms that can be interconnected with up to 23 other Kidde and Firex mains alarms.
Optional wireless capability using Wireless Alarm Base (RF-SFTP) for wire-free interconnection.
The ‘Slick’ range requires installation by a professionally qualified electrician and complies with UK Building Regulations for new housing and associated standards (Grade D, BS5839, Part 6).
- Unique fast-fit system with separate base plate, for ease of fitting and maintenance
- Integral, double-decker screwless terminal block for fast, push-fit connection
- Auto reset after activation with latching LED allowing the initiating alarm to be identified
- Separate Test and Hush buttons to test and temporarily silence nuisance alarms
- Alkaline back-up battery provides continuous operation in the event of mains failure
- Interconnectable with other Kidde mains smoke and heat alarms and Kidde mains CO alarmsusing ‘Smart Interconnect’ technology
- Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
- Wireless capability – use with optional Wireless Alarm Base (RF-SFTP) for RF interlink function
- Deep Base – allows easier wiring
Mains Heat Alarm Specification:
- Model 3SFW
- Power Supply 230V mains
- Temperature Range 0ºC to +40ºC
- Humidity Range Up to 93% Relative Humidity (RH) non-condensing
- Storage and Transport -20ºC to +60ºC and 5–95% relative humidity (RH) non-condensing
- Alarm Dimensions 135 x 135 x 70mm (including ‘Slick’ mounting base)
- Alarm Weight 274g
- Warranty 10 years
- Approvals BSI certified to BS5446 Part 2:2003
- CE tested and certified
- Associated Standard BS 5839 Part 6 Grade D
- Sensor Thermistor (Thermal resistor) within detection unit
- Sensitivity Complies with BS 5446 Part2:2003, as a Class A2 device, alarms between 54ºC and 70ºC
- Button Test Simulates the effect of heat at the sensor, checks electronics and sounder
- Automatic Self-test Circuitry is tested every 40 seconds and unit beeps if fault is detected
- Supply Voltage 230V AC, 50 Hz (nominal UK voltage)
- Power Consumption Maximum 80mA
- Battery Back-up User-replaceable alkaline 9V battery (MX1604)
- Battery Monitoring Battery is monitored and unit emits a single chirp every 40 seconds if a fault is present
- Low Battery Warning 30-day low battery indicator
- Power-on Indicator Continuous green LED
- Alarm Sounder Electronic piezo-electric sounder (T3 pattern sound - three pulses - space - three pulses)
- Sound Output 85dB (A) minimum at 3 metres
- Alarm Frequency 3.2 kHz typical
- Alarm Status Red LED flashes rapidly, typically once every 2/3 seconds = unit sensing a fire event
- Red LED double flashes every 30 seconds = unit is triggering unit (press test button to unlatch)
- Red LED flashes once every ten seconds = in hush condition (auto-reset after 7 minutes)
- Red LED flashes once every 35 seconds = normal quiescent operation
- Interconnection Up to 24 units (smoke, heat and CO) can be hardwire interconnected using SMART® interconnect system with optional control (see below)
- Up to 15 units can be wireless interconnected using appropriate Wireless Base RF-SFTP
- Optional Controls Wireless Base Remote Test and Hush Unit (KN-RTH-RF) when used with Wireless Base
- Fixing ‘Slick’ mounting deep base as supplied
- Base Cable Connect. Screwless Terminal Block with slot release feature for conductor
Please note: Alarms are sold individually.
Data Sheet:
Data Sheet for 2SFWData Sheet for 3SFW
Instruction Manual:
Instruction Manual for 2SFWInstruction Manual for 3SFW