{"title":"Schneider Easy9 6kA RCBO's","description":"\u003cp\u003eSchneider Electric Easy9 6kA RCBO Devices\u003c\/p\u003e","products":[{"product_id":"ez9d16806","title":"Schneider Electric EZ9D16806 6A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16806 6A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 6 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16806\" title=\"Data Sheet for EZ9D16806\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668737122,"sku":"EZ9D16806","price":22.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_5c5948b1-2728-404c-8a7f-78b9c11bfb38.jpg?v=1759245876"},{"product_id":"ez9d16810","title":"Schneider Electric EZ9D16810 10A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16810 10A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 10 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16810\" title=\"Data Sheet for EZ9D16810\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668769890,"sku":"EZ9D16810","price":22.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_30e3d67a-ebd0-492f-b8a6-57a5587a8f62.jpg?v=1759245875"},{"product_id":"ez9d16816","title":"Schneider Electric EZ9D16816 16A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16816 16A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 16 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16816\" title=\"Data Sheet for EZ9D16816\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668802658,"sku":"EZ9D16816","price":22.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_0c0f16f7-e1eb-407b-9ff1-efb85b834439.jpg?v=1759245874"},{"product_id":"ez9d16820","title":"Schneider Electric EZ9D16820 20A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16820 20A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 20 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16820\" title=\"Data Sheet for EZ9D16820\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668835426,"sku":"EZ9D16820","price":22.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_ce2618d1-4a83-4e1d-bfa6-d82ccb3bd312.jpg?v=1759245872"},{"product_id":"ez9d16832","title":"Schneider Electric EZ9D16832 32A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16832 32A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 32 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16832\" title=\"Data Sheet for EZ9D16832\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668868194,"sku":"EZ9D16832","price":22.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_32ccfb1a-0f6a-4018-9ce5-092cf9badb8a.jpg?v=1759245872"},{"product_id":"ez9d16840","title":"Schneider Electric EZ9D16840 40A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16840 40A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 40 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16840\" title=\"Data Sheet for EZ9D16840\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668900962,"sku":"EZ9D16840","price":22.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_8778e9c7-d6d4-4f6a-ae3c-cb04025c2ff2.jpg?v=1759245870"},{"product_id":"ez9d16850","title":"Schneider Electric EZ9D16850 50A 1P+N B Curve 30mA Type A RCBO","description":"\u003ch4\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSchneider Electric EZ9D16850 50A 1P+N B Curve 30mA Type A RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003e \n\u003cp\u003eThis Easy9 is a modular residual current breaker with overcurrent protection (RCBO). Protection of cable from overloads. Protection of persons from electric shocks by direct contact (30 mA sensitivity). Can be fitted instead of a miniature circuit breaker for complete protection of one circuit. Certified compliant to BS EN61009-1. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC\/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C\u003c\/p\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eRange: Easy9\u003c\/li\u003e\n\u003cli\u003eProduct or component type: Residual current breaker with overcurrent protection (RCBO)\u003c\/li\u003e\n\u003cli\u003eDevice short name: Easy9 RCBO\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + Ns\u003c\/li\u003e\n\u003cli\u003eNeutral position: Left\u003c\/li\u003e\n\u003cli\u003erated current: 50 A\u003c\/li\u003e\n\u003cli\u003eEarthing system: TN\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC\u003c\/li\u003e\n\u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n\u003cli\u003eCurve code: B\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection time delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection class: Type A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000 A Icn at 230 V AC 50 Hz conforming to BS EN 61009-1\u003c\/li\u003e\n\u003cli\u003eComplementary: \u003c\/li\u003e\n\u003cli\u003eDevice application: Distribution\u003c\/li\u003e\n\u003cli\u003eDevice location in system: Outgoer\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eNetwork frequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] rated operational voltage: 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003emagnetic tripping limit: 3...5 x In\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eResidual current tripping technology: Voltage dependent functional earth\u003c\/li\u003e\n\u003cli\u003eLimitation class: 3\u003c\/li\u003e\n\u003cli\u003e[Ui] rated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003e[Uimp] rated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n\u003cli\u003eContact position indicator: Yes\u003c\/li\u003e\n\u003cli\u003eControl type: Toggle\u003c\/li\u003e\n\u003cli\u003emounting support: DIN rail\u003c\/li\u003e\n\u003cli\u003e9 mm pitches: 2\u003c\/li\u003e\n\u003cli\u003eHeight: 110 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eNet weight: 180g \u003c\/li\u003e\n\u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 10000 cycles\u003c\/li\u003e\n\u003cli\u003eElectrical durability: 4000 cycles 230 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eConnections - terminals: Tunnel type terminal (top) 25 mm² rigid\nTunnel type terminal (bottom) 16 mm² rigid\nTunnel type terminal (bottom) 16 mm² flexible\nCable (top) 2 cable(s) flexible\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2 N.m top or bottom\u003c\/li\u003e\n\u003cli\u003eEarth-leakage protection: Integrated \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.se.com\/uk\/en\/product\/download-pdf\/EZ9D16850\" title=\"Data Sheet for EZ9D16850\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":40797668933730,"sku":"EZ9D16850","price":16.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/files_23c5a8ba-d8ec-4de7-b44c-e4cdae02a35b.jpg?v=1759245869"}],"url":"https:\/\/b2belectrical.com\/collections\/schneider-easy9-6ka-rcbos\/current-rating_16a.oembed","provider":"B2Belectrical.com","version":"1.0","type":"link"}