{"title":"LIVE Electrical Commercial RCBOs 10kA","description":"","products":[{"product_id":"ra106b-030","title":"LIVE Electrical RA106B-030 Type A Single Module 6A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA106B-030 Type A Single Module 6A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 6A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA106B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293719138,"sku":"RA106B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030.webp?v=1730216677"},{"product_id":"ra106c-030","title":"LIVE Electrical RA106C-030 Type A Single Module 6A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA106C-030 Type A Single Module 6A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 6A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA106C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293751906,"sku":"RA106C-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_be04acca-b5d8-40f7-9dcc-e2f03c5ea4a2.webp?v=1730216678"},{"product_id":"ra110b-030","title":"LIVE Electrical RA110B-030 Type A Single Module 10A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA110B-030 Type A Single Module 10A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 10A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA110B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293784674,"sku":"RA110B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_32c7383e-4c22-4891-845b-76ac4883c64a.webp?v=1730216679"},{"product_id":"ra110c-030","title":"LIVE Electrical RA110C-030 Type A Single Module 10A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA110C-030 Type A Single Module 10A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 10A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA110C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293817442,"sku":"RA110C-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_7f858880-5fb7-4be2-ae8c-6e0656220841.webp?v=1730216683"},{"product_id":"ra116b-030","title":"LIVE Electrical RA116B-030 Type A Single Module 16A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA116B-030 Type A Single Module 16A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 16A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA116B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293850210,"sku":"RA116B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_1db704af-aed4-436f-8f8c-7823a3b526da.webp?v=1730216683"},{"product_id":"ra116c-030","title":"LIVE Electrical RA116C-030 Type A Single Module 16A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA116C-030 Type A Single Module 16A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 16A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA116C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293882978,"sku":"RA116C-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_9818c4dd-c3fa-49e6-9565-135749a038ae.webp?v=1730216685"},{"product_id":"ra120b-030","title":"LIVE Electrical RA120B-030 Type A Single Module 20A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA120B-030 Type A Single Module 20A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 20A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA120B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293915746,"sku":"RA120B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_dd4481cb-cf76-489a-80e1-57a79ae6fd36.webp?v=1730216686"},{"product_id":"ra120c-030","title":"LIVE Electrical RA120C-030 Type A Single Module 20A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA120C-030 Type A Single Module 20A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 20A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA120C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293948514,"sku":"RA120C-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_2cf1977a-3439-4ae2-aeb4-22af07dc28f9.webp?v=1730216689"},{"product_id":"ra125b-030","title":"LIVE Electrical RA125B-030 Type A Single Module 25A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA125B-030 Type A Single Module 25A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 25A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA125B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554293981282,"sku":"RA125B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_eb153c68-7c57-4e58-8918-2c0aa6634596.webp?v=1730216689"},{"product_id":"ra125c-030","title":"LIVE Electrical RA125C-030 Type A Single Module 25A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA125C-030 Type A Single Module 25A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 25A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA125C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554294014050,"sku":"RA125C-030","price":13.42,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_bd6df6e3-a166-43fd-bc9e-bc23058c5e51.webp?v=1730216692"},{"product_id":"ra132b-030","title":"LIVE Electrical RA132B-030 Type A Single Module 32A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA132B-030 Type A Single Module 32A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 32A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA132B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554294046818,"sku":"RA132B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_9a349f47-4cc2-42f3-af54-30d77358f165.webp?v=1730216691"},{"product_id":"ra132c-030","title":"LIVE Electrical RA132C-030 Type A Single Module 32A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA132C-030 Type A Single Module 32A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 32A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA132C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554294079586,"sku":"RA132C-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_a97008b0-e147-4260-b0cf-648a50f7860a.webp?v=1730216695"},{"product_id":"ra140b-030","title":"LIVE Electrical RA140B-030 Type A Single Module 40A B Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA140B-030 Type A Single Module 40A B Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 40A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: B.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA140B-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554294112354,"sku":"RA140B-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_a597e1ae-7130-4f05-9421-5125e45ad54c.webp?v=1730216696"},{"product_id":"ra140c-030","title":"LIVE Electrical RA140C-030 Type A Single Module 40A C Curve 10kA 30mA High Immunity RCBO","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eLIVE Electrical RA140C-030 Type A Single Module 40A C Curve 10kA 30mA High Immunity RCBO\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType A RCBO Single Module\u003c\/p\u003e\n\u003cp\u003eLIVE Electrical brand high immunity RCBO is an ideal solution for providing over current \u0026amp; earth leakage protection. They ensure reliable protection to people \u0026amp; installation in networks having pulsated DC, harmonics \u0026amp; transients currents, while maintaining continuity of supply by reducing nuisance tripping. Handle can be locked with pad-lock to prevent unwanted operation for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated current (In): 40A.\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230V AC.\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 10kA.\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30mA.\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C.\u003c\/li\u003e\n\u003cli\u003eElectrical endurance: 400 cycles.\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 100000 cycles.\u003c\/li\u003e\n\u003cli\u003eComplies with BS EN 61009-1.\u003c\/li\u003e\n\u003cli\u003eType: A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1720644075__RCBO+AFDD%20Instruction.pdf\" title=\"Data Sheet for RA140C-030\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for LIVE Electrical Catalogue:\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":41554294145122,"sku":"RA140C-030","price":13.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RA106B-030_bf987210-d030-46dc-a5ac-eff4f2c8d244.webp?v=1730216698"},{"product_id":"live-electrical-rtn306b-030n-3p-n-6a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN306B-030N 3P+N 6A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN306B-030N 3P+N 6A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN306B-030N\u003c\/strong\u003e is a high-performance \u003cstrong\u003eType A 3P+N RCBO\u003c\/strong\u003e designed to provide both residual current and overcurrent protection in three-phase systems. With a \u003cstrong\u003e6A B Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, this device ensures reliable protection against short circuits, overloads, and earth leakage faults in commercial, industrial, and light commercial applications.\u003c\/p\u003e\n  \u003cp\u003eManufactured to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, the RTN306B-030N offers robust performance and compliance for modern electrical installations. Its compact design and easy terminal access make installation straightforward, while the \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e ensures effective protection against AC and pulsating DC residual currents from electronic equipment and variable speed drives.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – ideal for resistive and light inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – protects against AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e \n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines short circuit, overload, and earth leakage protection in a single compact device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures enhanced system safety.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity suitable for circuits containing modern electronic loads.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping provides reliable protection for resistive or low-inductance circuits.\u003c\/li\u003e\n    \u003cli\u003eQuick and easy installation with clearly marked terminals.\u003c\/li\u003e\n    \u003cli\u003eIdeal for use in three-phase distribution boards, EV installations, and machinery control panels.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN306B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071375229,"sku":"RTN306B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N.webp?v=1760054052"},{"product_id":"live-electrical-rtn310b-030n-3p-n-10a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN310B-030N 3P+N 10A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN310B-030N 3P+N 10A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN310B-030N\u003c\/strong\u003e is a high-quality \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e that provides combined protection against overload, short circuit, and earth leakage faults in \u003cstrong\u003ethree-phase electrical systems\u003c\/strong\u003e. With a \u003cstrong\u003e10A B Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, this RCBO ensures safe and reliable operation in commercial, industrial, and light commercial installations.\u003c\/p\u003e\n  \u003cp\u003eCompliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN310B-030N offers superior electrical protection and consistent performance. Its \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e makes it suitable for circuits with electronic loads or equipment that may generate pulsating DC residual currents, such as variable speed drives, EV chargers, and LED lighting systems.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – ideal for resistive and light inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eProvides combined overcurrent and residual current protection in one compact device.\u003c\/li\u003e\n    \u003cli\u003eHigh 10kA breaking capacity for dependable protection in demanding installations.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity ensures protection from both AC and pulsating DC leakage currents.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping characteristic ideal for standard lighting, heating, and socket outlet circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact design with easy-access terminals for fast installation and secure wiring.\u003c\/li\u003e\n    \u003cli\u003ePerfect for use in commercial boards, distribution panels, and EV charger systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN310B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071407997,"sku":"RTN310B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_4cb8b675-e62c-4233-86e2-6e58cec5cdea.webp?v=1760054056"},{"product_id":"live-electrical-rtn316b-030n-3p-n-16a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN316B-030N 3P+N 16A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN316B-030N 3P+N 16A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN316B-030N\u003c\/strong\u003e is a reliable \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to deliver complete protection for \u003cstrong\u003ethree-phase electrical installations\u003c\/strong\u003e. Combining overload, short circuit, and earth leakage protection in one compact device, it is ideal for commercial, industrial, and light commercial environments. With a \u003cstrong\u003e16A B Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, this RCBO ensures dependable performance and enhanced circuit safety.\u003c\/p\u003e\n  \u003cp\u003eConforming to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, the RTN316B-030N offers both performance and compliance for modern electrical systems. Its \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e allows for detection of both AC and pulsating DC residual currents, making it suitable for circuits with modern loads such as EV chargers, variable speed drives, and LED lighting installations.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – suitable for resistive and light inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines short circuit, overload, and earth leakage protection in a single compact device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity for enhanced reliability and safety in demanding circuits.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity suitable for modern electronic and mixed-load installations.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping – ideal for standard lighting, heating, and socket outlet applications.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design with clear labelling for easy identification and wiring.\u003c\/li\u003e\n    \u003cli\u003ePerfect for use in commercial distribution boards, workshops, and small industrial systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN316B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071440765,"sku":"RTN316B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_9191623a-a85f-47a0-aba4-3c27390fc3f9.webp?v=1760054059"},{"product_id":"live-electrical-rtn320b-030n-3p-n-20a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN320B-030N 3P+N 20A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN320B-030N 3P+N 20A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN320B-030N\u003c\/strong\u003e is a dependable \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to provide complete protection for \u003cstrong\u003ethree-phase installations\u003c\/strong\u003e against overload, short circuit, and earth leakage faults. With a \u003cstrong\u003e20A B Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it is ideal for both commercial and industrial environments where safety, performance, and compliance are essential.\u003c\/p\u003e\n  \u003cp\u003eEngineered in accordance with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN320B-030N ensures high-quality operation and durability. Its \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e allows detection of both AC and pulsating DC residual currents, making it suitable for protecting modern electrical loads such as LED lighting systems, EV chargers, and electronic devices that generate DC leakage currents.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 20A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – suitable for resistive and low-inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in a single device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures reliable performance in demanding three-phase installations.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity provides protection from both AC and pulsating DC residual currents.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping characteristic ideal for lighting, heating, and socket outlet circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design allows for easy installation and clear circuit identification.\u003c\/li\u003e\n    \u003cli\u003ePerfect for commercial distribution panels, EV charging systems, and small industrial units.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN320B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071473533,"sku":"RTN320B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_f681624f-0ed1-4e74-afbd-5ef6e482337f.webp?v=1760054063"},{"product_id":"live-electrical-rtn325b-030n-3p-n-25a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN325B-030N 3P+N 25A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN325B-030N 3P+N 25A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN325B-030N\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed for \u003cstrong\u003ethree-phase systems\u003c\/strong\u003e that require comprehensive circuit protection. Combining overcurrent, short circuit, and earth leakage protection in one compact device, this 25A RCBO offers exceptional reliability for both commercial and industrial applications. With a \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it ensures safe operation even under demanding load conditions.\u003c\/p\u003e\n  \u003cp\u003eFully compliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN325B-030N provides Type A protection against both AC and pulsating DC residual currents, making it ideal for use with modern electronic equipment such as LED lighting, EV chargers, and variable frequency drives. Its robust design and easy terminal access simplify installation and maintenance while ensuring long-term performance and safety.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – suitable for resistive and lightly inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in one device.\u003c\/li\u003e\n    \u003cli\u003e10kA breaking capacity for dependable protection in high-demand circuits.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity offers protection against AC and pulsating DC leakage currents.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping makes it ideal for standard lighting, heating, and outlet circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design ensures easy installation and clear labelling.\u003c\/li\u003e\n    \u003cli\u003eSuitable for commercial boards, EV installations, and industrial distribution systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN325B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071539069,"sku":"RTN325B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_c5632e96-9414-4e9d-be2c-d05ae340c264.webp?v=1760054065"},{"product_id":"live-electrical-rtn332b-030n-3p-n-32a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN332B-030N 3P+N 32A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN332B-030N 3P+N 32A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN332B-030N\u003c\/strong\u003e is a robust \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e that provides complete protection for \u003cstrong\u003ethree-phase installations\u003c\/strong\u003e. Combining overload, short circuit, and residual current protection into a single compact device, this RCBO offers superior performance and safety. With a \u003cstrong\u003e32A B Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it is ideally suited for a wide range of commercial, industrial, and light commercial applications.\u003c\/p\u003e\n  \u003cp\u003eConforming to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN332B-030N is designed to detect both AC and pulsating DC residual currents, ensuring protection against faults from modern equipment such as EV chargers, LED drivers, and variable speed drives. Its high reliability and compact modular design make it easy to install in standard three-phase consumer and distribution boards.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – suitable for resistive and low-inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eProvides overload, short circuit, and residual current protection in one compact unit.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures safe operation under fault conditions.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity ensures effective protection against AC and pulsating DC leakage currents.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping ideal for lighting, socket outlet, and general-purpose circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular construction simplifies installation and maintenance.\u003c\/li\u003e\n    \u003cli\u003ePerfect for commercial panels, industrial systems, and EV infrastructure.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN332B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071604605,"sku":"RTN332B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_f059c6b0-038b-46f5-ab63-5be6e4d8f29f.webp?v=1760054070"},{"product_id":"live-electrical-rtn340b-030n-3p-n-40a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN340B-030N 3P+N 40A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN340B-030N 3P+N 40A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN340B-030N\u003c\/strong\u003e is a powerful \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to provide comprehensive protection for \u003cstrong\u003ethree-phase electrical installations\u003c\/strong\u003e. Combining overcurrent, short circuit, and residual current protection in a single compact unit, this RCBO delivers superior reliability and performance. With a \u003cstrong\u003e40A B Curve tripping characteristic\u003c\/strong\u003e and a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it’s built to handle demanding electrical environments found in commercial and industrial applications.\u003c\/p\u003e\n  \u003cp\u003eFully compliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN340B-030N offers \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e, detecting both AC and pulsating DC residual currents for improved protection of modern electrical equipment such as EV chargers, LED drivers, and electronic control systems. Its durable and modular design allows for straightforward installation and long-lasting safety assurance.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – ideal for resistive and low-inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in one device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures safe operation under fault conditions.\u003c\/li\u003e\n    \u003cli\u003eType A protection detects both AC and pulsating DC leakage currents.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping characteristic suitable for general-purpose lighting and socket circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular construction simplifies installation and maintenance.\u003c\/li\u003e\n    \u003cli\u003eIdeal for use in commercial distribution boards, workshops, and industrial systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN340B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071670141,"sku":"RTN340B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_81d19df6-81be-4a6b-8fbe-cf538be50656.webp?v=1760054072"},{"product_id":"live-electrical-rtn350b-030n-3p-n-50a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN350B-030N 3P+N 50A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN350B-030N 3P+N 50A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN350B-030N\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to deliver comprehensive circuit protection for \u003cstrong\u003ethree-phase installations\u003c\/strong\u003e. Offering overload, short circuit, and residual current protection in a single compact unit, this 50A RCBO is ideal for heavy-duty commercial and industrial systems. With a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e and \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e, it ensures safe and reliable operation across demanding electrical environments.\u003c\/p\u003e\n  \u003cp\u003eFully compliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN350B-030N provides \u003cstrong\u003eType A residual current protection\u003c\/strong\u003e, detecting both AC and pulsating DC fault currents. Its robust design makes it suitable for protecting sensitive electronic equipment such as EV chargers, HVAC systems, and LED lighting installations, ensuring long-term safety and performance.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 50A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – suitable for resistive and low-inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and earth leakage protection in one compact device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures maximum safety under fault conditions.\u003c\/li\u003e\n    \u003cli\u003eType A protection detects both AC and pulsating DC residual currents.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping ideal for standard lighting and socket outlet circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design fits easily into commercial and industrial distribution boards.\u003c\/li\u003e\n    \u003cli\u003eProvides reliable and efficient circuit protection for high-load installations.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN350B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071702909,"sku":"RTN350B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_b25e9676-4aae-44d1-9040-411752a0c6c2.webp?v=1760054072"},{"product_id":"live-electrical-rtn363b-030n-3p-n-63a-b-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN363B-030N 3P+N 63A B Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN363B-030N 3P+N 63A B Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN363B-030N\u003c\/strong\u003e is a high-capacity \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e engineered to provide reliable protection for \u003cstrong\u003ethree-phase electrical systems\u003c\/strong\u003e. Designed for demanding commercial and industrial installations, this 63A RCBO combines \u003cstrong\u003eoverload, short circuit, and residual current protection\u003c\/strong\u003e in one robust, space-saving unit. With a \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e and \u003cstrong\u003eB Curve tripping characteristic\u003c\/strong\u003e, it delivers dependable performance and safety under high-load conditions.\u003c\/p\u003e\n  \u003cp\u003eFully compliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN363B-030N features \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e, detecting both AC and pulsating DC residual currents. This ensures optimal protection for sensitive equipment such as EV chargers, industrial machinery, LED lighting systems, and HVAC units. Its durable design and consistent operation make it a trusted choice for professional installers.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 63A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B Curve – suitable for resistive and low-inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and earth leakage protection in a single device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity for enhanced safety and circuit resilience.\u003c\/li\u003e\n    \u003cli\u003eType A protection detects both AC and pulsating DC residual currents for modern installations.\u003c\/li\u003e\n    \u003cli\u003eB Curve tripping suitable for general-purpose and lighting circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design allows for simple installation in commercial distribution boards.\u003c\/li\u003e\n    \u003cli\u003eIdeal for high-load industrial and commercial environments.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN363B-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071735677,"sku":"RTN363B-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_5f622fb4-872f-405c-9789-70abe88b7d12.webp?v=1760054073"},{"product_id":"live-electrical-rtn306c-030n-3p-n-6a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN306C-030N 3P+N 6A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN306C-030N 3P+N 6A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN306C-030N\u003c\/strong\u003e is a compact and high-performance \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e offering combined \u003cstrong\u003eoverload, short circuit, and residual current protection\u003c\/strong\u003e for three-phase systems. With a \u003cstrong\u003e6A C Curve tripping characteristic\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, this RCBO ensures safety and reliability in commercial, industrial, and light manufacturing environments. Designed for modern electrical systems, it provides essential protection for circuits with higher inrush currents, such as motors or transformers.\u003c\/p\u003e\n  \u003cp\u003eCompliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN306C-030N features \u003cstrong\u003eType A residual current detection\u003c\/strong\u003e, responding to both AC and pulsating DC fault currents — making it ideal for installations with electronic loads such as LED lighting, EV chargers, and automation systems.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – ideal for inductive and motor-type loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in one device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures safe disconnection under fault conditions.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping characteristic for circuits with moderate inrush currents (e.g., motors, compressors).\u003c\/li\u003e\n    \u003cli\u003eType A residual protection ideal for detecting AC and pulsating DC fault currents.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design suitable for commercial and industrial distribution boards.\u003c\/li\u003e\n    \u003cli\u003eProvides reliable circuit protection for sensitive and high-demand equipment.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN306C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071768445,"sku":"RTN306C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_94a68fe1-1110-4724-a941-a8c188fdb3d2.webp?v=1760054078"},{"product_id":"live-electrical-rtn310c-030n-3p-n-10a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN310C-030N 3P+N 10A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN310C-030N 3P+N 10A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN310C-030N\u003c\/strong\u003e is a durable and high-performance \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to provide comprehensive \u003cstrong\u003eoverload, short circuit, and residual current protection\u003c\/strong\u003e in three-phase electrical systems. With a \u003cstrong\u003e10A rating\u003c\/strong\u003e and \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e, it is ideal for circuits with moderate inductive loads such as motors, fans, and transformers, ensuring stability and safety during operation.\u003c\/p\u003e\n  \u003cp\u003eTested to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, this RCBO features \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e, capable of detecting both AC and pulsating DC fault currents, making it suitable for modern installations that include electronic equipment and LED lighting systems. The compact modular design allows for easy integration into industrial and commercial distribution boards.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – suitable for moderate inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eProvides overload, short circuit, and earth leakage protection in one device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity for enhanced circuit protection and reliability.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping characteristic designed for circuits with moderate inrush currents.\u003c\/li\u003e\n    \u003cli\u003eType A protection suitable for circuits with AC and pulsating DC residual currents.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design fits seamlessly into three-phase distribution boards.\u003c\/li\u003e\n    \u003cli\u003eIdeal for use in commercial, industrial, and mixed-load applications.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN310C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071801213,"sku":"RTN310C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_4f56185e-7f69-4ef2-9e51-ec6433210ed1.webp?v=1760054080"},{"product_id":"live-electrical-rtn316c-030n-3p-n-16a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN316C-030N 3P+N 16A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN316C-030N 3P+N 16A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN316C-030N\u003c\/strong\u003e is a reliable and compact \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e that combines \u003cstrong\u003eoverload, short circuit, and residual current protection\u003c\/strong\u003e into one high-performance device. With a \u003cstrong\u003e16A rated current\u003c\/strong\u003e and a \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e, it is ideal for protecting circuits with moderate inductive loads, such as small motors, pumps, or lighting systems in commercial and industrial applications.\u003c\/p\u003e\n  \u003cp\u003eFully compliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, this RCBO features \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e to detect both AC and pulsating DC fault currents. Designed for use in modern electrical systems, it offers dependable safety for installations containing sensitive electronic components, while maintaining consistent performance under demanding conditions.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – designed for circuits with moderate inrush currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and earth leakage protection in a single compact unit.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures safe operation during fault conditions.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping for reliable performance with inductive loads such as motors and HVAC systems.\u003c\/li\u003e\n    \u003cli\u003eType A protection ideal for detecting AC and pulsating DC faults in modern installations.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design suitable for commercial and industrial distribution boards.\u003c\/li\u003e\n    \u003cli\u003eRobust and efficient protection for mixed-load and motor-driven systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN316C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071833981,"sku":"RTN316C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_a6a691ec-3e1a-4aeb-b235-a49156e2b1d9.webp?v=1760054081"},{"product_id":"live-electrical-rtn320c-030n-3p-n-20a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN320C-030N 3P+N 20A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN320C-030N 3P+N 20A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN320C-030N\u003c\/strong\u003e is a dependable \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to deliver superior \u003cstrong\u003eoverload, short circuit, and residual current protection\u003c\/strong\u003e for three-phase installations. With a \u003cstrong\u003e20A rated current\u003c\/strong\u003e and a \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e, this RCBO is ideal for circuits with moderate inductive or capacitive loads such as air conditioning units, motors, and lighting systems in commercial and industrial applications.\u003c\/p\u003e\n  \u003cp\u003eComplying with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, the RTN320C-030N features \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e to detect both AC and pulsating DC fault currents, ensuring enhanced electrical safety for modern equipment. Its compact and modular design allows for quick installation, making it a reliable solution for professionals looking for robust protection in demanding environments.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 20A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – suitable for circuits with moderate inrush currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and earth leakage protection in one compact device.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity ensures safety in demanding electrical conditions.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping characteristic ideal for inductive or mixed-load applications.\u003c\/li\u003e\n    \u003cli\u003eType A protection suitable for detecting both AC and pulsating DC faults.\u003c\/li\u003e\n    \u003cli\u003eCompact modular construction for easy integration into distribution panels.\u003c\/li\u003e\n    \u003cli\u003ePerfect for commercial, industrial, and mixed-use electrical systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN320C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071866749,"sku":"RTN320C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_2071b917-50e6-4e9f-8030-7a6bf9a0f909.webp?v=1760054081"},{"product_id":"live-electrical-rtn325c-030n-3p-n-25a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN325C-030N 3P+N 25A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN325C-030N 3P+N 25A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN325C-030N\u003c\/strong\u003e is a high-quality \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e that delivers exceptional protection against \u003cstrong\u003eoverload, short circuit, and residual current faults\u003c\/strong\u003e. With a \u003cstrong\u003e25A current rating\u003c\/strong\u003e and a \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e, this unit is perfectly suited for circuits with moderate inductive or capacitive loads such as air conditioning systems, small machinery, and mixed-load applications in industrial and commercial settings.\u003c\/p\u003e\n  \u003cp\u003eFully compliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, this RCBO combines reliability with efficiency. Its \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e ensures detection of both AC and pulsating DC leakage currents, offering superior protection for modern electrical systems incorporating sensitive electronic devices. Compact, robust, and easy to install, it is a dependable choice for professional installations.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – suitable for circuits with moderate inrush currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eOffers combined protection against overloads, short circuits, and earth leakage faults.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity for enhanced circuit safety and reliability.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping characteristic optimised for inductive and mixed-load applications.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity ensures detection of both AC and pulsating DC fault currents.\u003c\/li\u003e\n    \u003cli\u003eCompact and modular design allows easy integration into three-phase distribution systems.\u003c\/li\u003e\n    \u003cli\u003eIdeal for industrial, commercial, and light manufacturing environments.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN325C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071899517,"sku":"RTN325C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_37393361-ef29-4cf8-ad27-38208398c9a5.webp?v=1760054086"},{"product_id":"live-electrical-rtn332c-030n-3p-n-32a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN332C-030N 3P+N 32A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN332C-030N 3P+N 32A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN332C-030N\u003c\/strong\u003e is a robust \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to provide comprehensive protection against \u003cstrong\u003eoverload, short circuit, and residual current faults\u003c\/strong\u003e. With a \u003cstrong\u003e32A rated current\u003c\/strong\u003e and a \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e, this device is ideal for circuits supplying moderate inductive loads such as motors, HVAC systems, and lighting installations across commercial and industrial environments.\u003c\/p\u003e\n  \u003cp\u003eManufactured to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, the RTN332C-030N ensures safety and reliability. Its \u003cstrong\u003eType A residual current detection\u003c\/strong\u003e covers both AC and pulsating DC fault currents, making it suitable for protecting modern equipment that incorporates electronic components and variable speed drives. Compact and easy to install, this RCBO is an excellent solution for three-phase distribution systems requiring precision protection.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – designed for circuits with moderate inrush currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in one compact unit.\u003c\/li\u003e\n    \u003cli\u003e10kA high breaking capacity for dependable fault protection in high-demand systems.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping suitable for mixed or moderately inductive loads.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity ideal for detecting both AC and pulsating DC faults.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design for quick and efficient installation.\u003c\/li\u003e\n    \u003cli\u003ePerfect for commercial, industrial, and workshop applications.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN332C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071932285,"sku":"RTN332C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_ea2de55a-ea65-4f51-abf9-84e512ea02df.webp?v=1760054088"},{"product_id":"live-electrical-rtn340c-030n-3p-n-40a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN340C-030N 3P+N 40A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN340C-030N 3P+N 40A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN340C-030N\u003c\/strong\u003e is a durable and high-performance \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e that provides complete \u003cstrong\u003eoverload, short circuit, and residual current protection\u003c\/strong\u003e. With a \u003cstrong\u003e40A rated current\u003c\/strong\u003e and \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e, it is ideal for use in circuits supplying moderate inductive loads, such as motors, compressors, HVAC systems, and lighting networks in commercial and industrial environments.\u003c\/p\u003e\n  \u003cp\u003eEngineered to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e standards, this RCBO combines advanced electrical safety with reliability. Its \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e enables the detection of both AC and pulsating DC fault currents, ensuring comprehensive protection for circuits connected to modern equipment and electronic devices. The compact modular design makes it easy to install in any three-phase distribution setup.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – designed for moderate inrush or inductive loads\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC fault currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eProvides combined overload, short circuit, and earth leakage protection in one device.\u003c\/li\u003e\n    \u003cli\u003eHigh 10kA breaking capacity ensures reliable operation in demanding installations.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping performance ideal for circuits with moderate inductive characteristics.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity for detection of AC and pulsating DC residual currents.\u003c\/li\u003e\n    \u003cli\u003eModular and compact design for easy installation in distribution boards.\u003c\/li\u003e\n    \u003cli\u003ePerfect for commercial, industrial, and workshop electrical systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN340C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071965053,"sku":"RTN340C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_9b4c5de8-18c9-45a1-b33c-640375691324.webp?v=1760054089"},{"product_id":"live-electrical-rtn350c-030n-3p-n-50a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN350C-030N 3P+N 50A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN350C-030N 3P+N 50A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN350C-030N\u003c\/strong\u003e is a reliable and high-capacity \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed for use in \u003cstrong\u003ethree-phase electrical installations\u003c\/strong\u003e. Offering \u003cstrong\u003e50A rated current\u003c\/strong\u003e and \u003cstrong\u003eC Curve tripping characteristics\u003c\/strong\u003e, this RCBO provides dependable protection against \u003cstrong\u003eoverload, short circuit, and residual current faults\u003c\/strong\u003e. It is ideal for circuits with moderate inrush currents, such as motor-driven equipment, lighting systems, and industrial machinery.\u003c\/p\u003e\n  \u003cp\u003eCompliant with \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN350C-030N ensures safe operation and high performance. With \u003cstrong\u003eType A residual current detection\u003c\/strong\u003e, it effectively detects both AC and pulsating DC fault currents, ensuring enhanced safety for installations incorporating sensitive or electronic equipment. Its compact modular design allows for straightforward installation into distribution boards and control panels.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 50A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – suitable for moderate inductive or mixed-load circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in a single compact device.\u003c\/li\u003e\n    \u003cli\u003e10kA breaking capacity ensures reliability in high-demand environments.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping for circuits with moderate inductive loads such as motors and pumps.\u003c\/li\u003e\n    \u003cli\u003eType A sensitivity for detecting AC and pulsating DC fault currents.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design for efficient installation in distribution boards.\u003c\/li\u003e\n    \u003cli\u003eSuitable for industrial, commercial, and light manufacturing applications.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN350C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124071997821,"sku":"RTN350C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_8ca13879-d23e-4057-a09f-6d2b76eb9571.webp?v=1760054089"},{"product_id":"live-electrical-rtn363c-030n-3p-n-63a-c-curve-10ka-30ma-type-a-rcbo","title":"LIVE Electrical RTN363C-030N 3P+N 63A C Curve 10kA 30mA Type A RCBO","description":"\u003csection\u003e\n  \u003ch2\u003eLIVE Electrical RTN363C-030N 3P+N 63A C Curve 10kA 30mA Type A RCBO\u003c\/h2\u003e\n\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RTN363C-030N\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003e3P+N Type A RCBO\u003c\/strong\u003e designed to provide comprehensive \u003cstrong\u003eoverload, short circuit, and earth leakage protection\u003c\/strong\u003e in three-phase installations. With a \u003cstrong\u003e63A rated current\u003c\/strong\u003e and \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, this RCBO delivers dependable safety for high-demand industrial, commercial, and manufacturing environments where power reliability is crucial.\u003c\/p\u003e\n  \u003cp\u003eConforming to \u003cstrong\u003eBS EN 61009-1\u003c\/strong\u003e, the RTN363C-030N features a \u003cstrong\u003eC Curve tripping characteristic\u003c\/strong\u003e suitable for circuits with moderate inductive loads, such as motors, HVAC systems, and control panels. Its \u003cstrong\u003eType A sensitivity\u003c\/strong\u003e ensures the detection of both AC and pulsating DC residual currents, offering advanced protection for installations incorporating electronic equipment and variable frequency drives.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Specifications\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 63A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Voltage (Ue):\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity (Icn):\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Residual Current:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePole Configuration:\u003c\/strong\u003e 3P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C Curve – designed for moderate inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Type:\u003c\/strong\u003e Type A – detects both AC and pulsating DC leakage currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Capacity:\u003c\/strong\u003e\n      \u003cul\u003e\n        \u003cli\u003eInput: up to 16mm²\u003c\/li\u003e\n        \u003cli\u003eOutput: up to 10mm²\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e BS EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eCombines overload, short circuit, and residual current protection in one compact device.\u003c\/li\u003e\n    \u003cli\u003eHigh 10kA breaking capacity ensures dependable protection under fault conditions.\u003c\/li\u003e\n    \u003cli\u003eType A detection for both AC and pulsating DC earth leakage faults.\u003c\/li\u003e\n    \u003cli\u003eC Curve tripping characteristic suitable for inductive and mixed-load circuits.\u003c\/li\u003e\n    \u003cli\u003eCompact modular design for fast installation in distribution boards.\u003c\/li\u003e\n    \u003cli\u003ePerfect for high-load industrial and commercial three-phase systems.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/documents\/datasheets\/1750423847__RCBO%20-%203%20Phase%20Type%20A%20-%20RTN%20%20datasheet.pdf\" title=\"Data Sheet for RTN363C-030N\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download Data Sheet (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n  \u003cp\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" title=\"LIVE Electrical Catalogue\" target=\"_blank\" rel=\"noopener\"\u003e\n       Download LIVE Electrical Catalogue (PDF)\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57124072063357,"sku":"RTN363C-030N","price":54.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RTN350C-030N_5ae8df86-bcfb-4ef6-a5d6-526bf44abadf.webp?v=1760054094"},{"product_id":"live-electrical-rka120b-030-20a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA120B-030 20A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA120B-030 20A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA120B-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to deliver enhanced safety and dependable performance in modern electrical installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a single space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eWith a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain in service while isolating only the faulty circuit. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for today’s increasingly electronic loads.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e20A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a high \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA120B-030 offers effective protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 20A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475109757,"sku":"RKA120B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_83e1ade4-3dcb-4fa2-8e04-9aae479f23eb.webp?v=1766633486"},{"product_id":"live-electrical-rka125b-030-25a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA125B-030 25A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA125B-030 25A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA125B-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to deliver enhanced safety and reliable performance in modern electrical installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a single, space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is isolated. The \u003cstrong\u003eType A protection\u003c\/strong\u003e allows detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for today’s electronically controlled loads.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e25A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a high \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA125B-030 provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475208061,"sku":"RKA125B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_fa12c7b2-0b9f-4e21-8580-e483131cd94b.webp?v=1766633486"},{"product_id":"live-electrical-rka106b-030-6a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA106B-030 6A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA106B-030 6A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA106B-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to deliver high levels of safety and reliability in modern electrical installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a single device.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected, improving system continuity and safety. The \u003cstrong\u003eType A functionality\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for a wide range of domestic and commercial applications.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e6A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a high \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA106B-030 provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for enhanced circuit safety\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for space-efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475273597,"sku":"RKA106B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030.webp?v=1766633484"},{"product_id":"live-electrical-rka125c-030-25a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA125C-030 25A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA125C-030 25A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA125C-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to provide high levels of electrical safety and reliability in modern installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e into a single, space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eSupplied with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e allows detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for today’s electronic and inductive loads.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA125C-030 is ideal for circuits with higher inrush currents. Rated at \u003cstrong\u003e25A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 25A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475306365,"sku":"RKA125C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_195e7822-881b-4358-a47c-178fa7f5e69f.webp?v=1766633484"},{"product_id":"live-electrical-rka106c-030-6a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA106C-030 6A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA106C-030 6A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA106C-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to provide enhanced safety and reliability in modern electrical installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a single space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eSupplied with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while isolating only the faulty circuit. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for a wide range of modern electrical loads.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA106C-030 is ideal for circuits with higher inrush currents. Rated at \u003cstrong\u003e6A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it provides dependable protection against electric shock, insulation faults and fire hazards.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 6A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475371901,"sku":"RKA106C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_b7b1bec3-6738-4e4f-9a09-2452d53f6620.webp?v=1766633486"},{"product_id":"live-electrical-rka116c-030-16a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA116C-030 16A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA116C-030 16A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA116C-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to deliver enhanced electrical safety and reliable performance in modern installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e into a single space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eSupplied with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e allows detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for contemporary electrical systems with electronic loads.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA116C-030 is ideal for circuits with higher inrush currents. Rated at \u003cstrong\u003e16A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475404669,"sku":"RKA116C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_50f46048-170b-47e9-8439-2039197afd9c.webp?v=1766633486"},{"product_id":"live-electrical-rka140b-030-40a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA140B-030 40A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA140B-030 40A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA140B-030 Type A RCBO\u003c\/strong\u003e is a high-capacity, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, engineered to deliver maximum safety and reliability in demanding electrical installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a compact, space-saving design.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while isolating only the faulty circuit. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for modern electrical systems with electronic loads.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e40A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA140B-030 provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage, even in higher-load circuits.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard and higher-load final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475437437,"sku":"RKA140B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_42bb6ed8-87fa-4598-845a-25876b99dde3.webp?v=1766633485"},{"product_id":"live-electrical-rka110b-030-10a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA110B-030 10A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA110B-030 10A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA110B-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to enhance safety and reliability in domestic, commercial and light industrial electrical installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e into a single device.\u003c\/p\u003e\n\n  \u003cp\u003eEquipped with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e allows detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for modern electrical loads.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e10A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA110B-030 provides effective protection against electric shock, insulation faults and potential fire hazards.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for enhanced safety and continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized format\u003c\/strong\u003e for space-efficient installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475470205,"sku":"RKA110B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_db7f2887-6461-43ad-a2b8-7f4a0193f3bd.webp?v=1766633485"},{"product_id":"live-electrical-rka116b-030-16a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA116B-030 16A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA116B-030 16A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA116B-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to deliver high levels of electrical safety and reliability in modern installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a single space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for a wide range of domestic and commercial applications.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e16A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA116B-030 provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 16A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475502973,"sku":"RKA116B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_009894b6-6ae0-4823-b214-d281f43f73e0.webp?v=1766633485"},{"product_id":"live-electrical-rka110c-030-10a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA110C-030 10A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA110C-030 10A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA110C-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to provide enhanced safety and reliability in modern electrical installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e into a single, space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eSupplied with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e allows detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for today’s electronic and inductive loads.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA110C-030 is ideal for circuits with higher inrush currents. Rated at \u003cstrong\u003e10A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it provides dependable protection against electric shock, insulation faults and fire hazards.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 10A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475568509,"sku":"RKA110C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_3e7ea501-119d-4edd-a984-24d6e1f2489f.webp?v=1766633486"},{"product_id":"live-electrical-rka132b-030-32a-1p-n-b-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA132B-030 32A 1P+N B Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA132B-030 32A 1P+N Type A RCBO B Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA132B-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, engineered to deliver high levels of safety and reliability in modern electrical installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e into a single space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A functionality\u003c\/strong\u003e allows detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for today’s electronically controlled loads.\u003c\/p\u003e\n\n  \u003cp\u003eRated at \u003cstrong\u003e32A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a high \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, the RKA132B-030 provides dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eB-curve tripping\u003c\/strong\u003e suitable for standard final circuits\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475634045,"sku":"RKA132B-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_d0a406ff-b8a2-4ba2-9762-e797ddc30391.webp?v=1766633485"},{"product_id":"live-electrical-rka140c-030-40a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA140C-030 40A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA140C-030 40A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA140C-030 Type A RCBO\u003c\/strong\u003e is a high-capacity, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to deliver maximum safety and dependable performance in demanding electrical installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a compact, space-saving format.\u003c\/p\u003e\n\n  \u003cp\u003eEquipped with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while isolating only the faulty circuit. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for modern electrical systems with electronic and inductive loads.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA140C-030 is ideal for circuits subject to higher inrush currents. Rated at \u003cstrong\u003e40A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it provides reliable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current and inductive load applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for enhanced safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 40A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475732349,"sku":"RKA140C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_e687a772-1c2d-4eb1-bdc9-1cf7e2be89f4.webp?v=1766633486"},{"product_id":"live-electrical-rka132c-030-32a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA132C-030 32A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA132C-030 32A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA132C-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, designed to provide high levels of safety and reliable performance in modern electrical installations. It integrates \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e into a single, space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eSupplied with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for today’s electronically controlled and inductive loads.\u003c\/p\u003e\n\n  \u003cp\u003eWith a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA132C-030 is ideal for circuits subject to higher inrush currents. Rated at \u003cstrong\u003e32A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it delivers dependable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 32A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475830653,"sku":"RKA132C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_fec5a07a-9ed2-40f5-aea8-e32fe166d347.webp?v=1766633482"},{"product_id":"live-electrical-rka120c-030-20a-1p-n-c-curve-10ka-30ma-type-a-bi-directional-rcbo","title":"LIVE Electrical RKA120C-030 20A 1P+N C Curve 10kA 30mA Type A Bi-Directional Compact RCBO","description":"\u003ch2\u003eLIVE Electrical RKA120C-030 20A 1P+N Type A RCBO C Curve 30mA 10kA Bi-Directional\u003c\/h2\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eProduct Overview\u003c\/h3\u003e\n  \u003cp\u003eThe \u003cstrong\u003eLIVE Electrical RKA120C-030 Type A RCBO\u003c\/strong\u003e is a compact, \u003cstrong\u003eMCB-sized residual current breaker with overcurrent protection\u003c\/strong\u003e, engineered to provide enhanced safety and dependable performance in modern electrical installations. It combines \u003cstrong\u003eswitching, isolation, overload protection and short-circuit protection\u003c\/strong\u003e within a single space-saving device.\u003c\/p\u003e\n\n  \u003cp\u003eSupplied with a \u003cstrong\u003eswitched neutral as standard\u003c\/strong\u003e, this RCBO ensures that healthy circuits remain energised while only the faulty circuit is disconnected. The \u003cstrong\u003eType A protection\u003c\/strong\u003e enables detection of both \u003cstrong\u003eAC and pulsating DC residual currents\u003c\/strong\u003e, making it suitable for contemporary electrical systems with electronic and inductive loads.\u003c\/p\u003e\n\n  \u003cp\u003eFeaturing a \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, the RKA120C-030 is ideal for circuits with higher inrush currents. Rated at \u003cstrong\u003e20A\u003c\/strong\u003e with a \u003cstrong\u003e30mA residual current sensitivity\u003c\/strong\u003e and a robust \u003cstrong\u003e10kA breaking capacity\u003c\/strong\u003e, it delivers reliable protection against electric shock, insulation faults and fire hazards caused by earth leakage.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eType A RCBO\u003c\/strong\u003e detects AC and pulsating DC residual currents\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eC-curve tripping\u003c\/strong\u003e suitable for higher inrush current applications\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitched neutral as standard\u003c\/strong\u003e for improved safety and circuit continuity\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBi-directional\u003c\/strong\u003e power flow capability\u003c\/li\u003e\n    \u003cli\u003eProvides \u003cstrong\u003eswitching and isolation\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eoverload\u003c\/strong\u003e and \u003cstrong\u003eshort circuits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProtection against \u003cstrong\u003eelectric shock\u003c\/strong\u003e and \u003cstrong\u003efire hazards\u003c\/strong\u003e caused by insulation faults\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact MCB-sized design\u003c\/strong\u003e for efficient consumer unit installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1P+N\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Current (In):\u003c\/strong\u003e 20A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTripping Curve:\u003c\/strong\u003e C\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResidual Current Sensitivity:\u003c\/strong\u003e 30mA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50\/60Hz\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Operating Voltage:\u003c\/strong\u003e 230\/240V~\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImpulse Withstand Voltage (Uimp):\u003c\/strong\u003e 4kV (1.2\/50µs)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity:\u003c\/strong\u003e 10kA\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDevice Type:\u003c\/strong\u003e Type A\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaximum Terminal Cable Size:\u003c\/strong\u003e 16mm²\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTerminal Torque:\u003c\/strong\u003e 2.5Nm\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirection of Supply:\u003c\/strong\u003e Bi-Directional\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch3\u003eDownloads\u003c\/h3\u003e\n  \u003cp\u003e\n    \u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0553\/2349\/2557\/files\/RCBO-_RKA_Type_A_10kA_Single_Module_-_Datasheet.pdf?v=1766566316\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to download the RKA Type A 10kA single-module RCBO data sheet\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    \u003cstrong\u003eLIVE Electrical Catalogue:\u003c\/strong\u003e\u003cbr\u003e\n    \u003ca href=\"https:\/\/www.liveelectrical.co.uk\/storage\/Files\/1726827606_20240919125921_0-live%20catalog-update0912%201.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\n      Click here to view the LIVE Electrical catalogue\n    \u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/section\u003e","brand":"LIVE Electrical","offers":[{"title":"Default Title","offer_id":57636475863421,"sku":"RKA120C-030","price":13.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/RKA106B-030_74bfd297-ddc5-4f81-ac4c-30f8d90b2e8c.webp?v=1766633483"}],"url":"https:\/\/b2belectrical.com\/collections\/live-electrical-commercial-rcbos-10ka\/modules_3.oembed","provider":"B2Belectrical.com","version":"1.0","type":"link"}