{"title":"HiSPEC 2CAS Commercial Fire Alarm System","description":"","products":[{"product_id":"hs2cas-he-sb","title":"HiSPEC HS2CAS\/HE\/SB 2CAS Heat Detector c\/w Sounder \u0026 Beacon","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/HE\/SB 2CAS Heat Detector c\/w Sounder \u0026amp; Beacon\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with Sounder\/ Flasher Base\u003c\/li\u003e\n\u003cli\u003eSoft Addressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eRemove LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Rate of Rise (Thermistor A1R)\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: Rate of Rise\/ Fixed Heat Trigger @57°C\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 152g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 308g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 5\u003c\/li\u003e\n\u003cli\u003eIncluded: Head, Sounder \u0026amp; Flasher Base\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/HE\/90F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.he-hs2cas.he.sb-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/HE\/SB\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179040448610,"sku":"HS2CAS\/HE\/SB","price":42.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.HE_55cd5c0f-82b7-451e-b897-101603dc9c88.jpg?v=1716943522"},{"product_id":"hs2cas-he-60f","title":"HiSPEC HS2CAS\/HE\/60F 2CAS 60' Fixed Heat Detector","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/HE\/60F 2CAS 60' Fixed Heat Detector\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with Sounder\/ Flasher Base\u003c\/li\u003e\n\u003cli\u003eSoft Addressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eRemove LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Rate of Rise (Thermistor A1R)\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: Rate of Rise\/ Fixed Heat Trigger @57°C\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 152g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 308g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 5\u003c\/li\u003e\n\u003cli\u003eIncluded: Head Only\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/HE\/60F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.he.60f-hs2cas.he.5b60f-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/HE\/60F\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179040907362,"sku":"HS2CAS\/HE\/60F","price":30.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/2cas-60-c-fixed-temp-heat-detector-head-only-with-base-with-sounder-flasher-base-2128-p.jpg?v=1716943523"},{"product_id":"hs2cas-rp","title":"HiSPEC HS2CAS\/RP Mains 2CAS Repeater Panel","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/RP Mains 2CAS Repeater Panel\u003c\/strong\u003e\u003c\/h4\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179040940130,"sku":"HS2CAS\/RP","price":249.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.RP.jpg?v=1716943525"},{"product_id":"hs2cas-iso","title":"HiSPEC HS2CAS\/ISO 2CAS Mains Isolate Switch, Red","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/ISO 2CAS Mains Isolate Switch, Red\u003c\/strong\u003e\u003c\/h4\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179040972898,"sku":"HS2CAS\/ISO","price":36.85,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/image-coming-soon-1_b2e85690-a098-4338-b2de-c5821bcc84d0.jpg?v=1716943526"},{"product_id":"hs2cas-sb-ip65","title":"HiSPEC HS2CAS\/SB-IP65 2CAS Weatherproof Sounder \u0026 Beacon IP65","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/SB-IP65 2CAS Weatherproof Sounder \u0026amp; Beacon IP65\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 Tone patterns selectable\u003c\/li\u003e\n\u003cli\u003eHoused in UL VO flame retardant ABS\u003c\/li\u003e\n\u003cli\u003e3 x 20mm knock outs (2 top, 1 bottom)\u003c\/li\u003e\n\u003cli\u003eAddressable via dip-switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 1.5mA\u003c\/li\u003e\n\u003cli\u003eAlarm Current: 5.4mA\u003c\/li\u003e\n\u003cli\u003eSounder Type: B\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -25°C ~ + 70°C\u003c\/li\u003e\n\u003cli\u003eSound Output @ 1m: 96.9dB +\/- 3dB\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP65\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 3 Part B\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/SB-IP65\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041005666,"sku":"HS2CAS\/SB-IP65","price":60.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.SB-IP67.jpg?v=1716943526"},{"product_id":"hs2cas-2zp","title":"HiSPEC HS2CAS\/2ZP Mains 2CAS Two Zone Panel","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/2ZP Mains 2CAS Two Zone Panel\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Zone, 4 Zone \u0026amp; 8 Zone available\u003c\/li\u003e\n\u003cli\u003eEach device is uniquely addressable\u003c\/li\u003e\n\u003cli\u003eCan be wired as radial loop\u003c\/li\u003e\n\u003cli\u003e15 Devices per zone\u003c\/li\u003e\n\u003cli\u003eSeparate sounder circuit not required\u003c\/li\u003e\n\u003cli\u003e2048 Event history log\u003c\/li\u003e\n\u003cli\u003eSurface mountable and recessed mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply Voltage: 230v ac 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 29v dc nominal (19-30v)\u003c\/li\u003e\n\u003cli\u003eLoop Sounder Circuit Supply: 2x Conventional, 28v nominal, 150mA (20-30v dc)\u003c\/li\u003e\n\u003cli\u003eFault Relay: 1xSELV@1A (normally energised)\u003c\/li\u003e\n\u003cli\u003eFire Relay: 1xSELV@1A\u003c\/li\u003e\n\u003cli\u003eDetection Circuits: 8 Radial Circuits (Max), 4 Loop Circuits (Max)\u003c\/li\u003e\n\u003cli\u003eLoop Sounder Circuit: 80 Sounder (Max)\u003c\/li\u003e\n\u003cli\u003eRepeater Panel Connection: RS485\u003c\/li\u003e\n\u003cli\u003eApproved to: BS5839-1 \u0026amp; 6\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54-2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/2ZP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/design\/button_-data-sheet.png?v=202d1171b08f05d602813a65d49ae269\" title=\"Data Sheet for HS2CAS\/2ZP\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041038434,"sku":"HS2CAS\/2ZP","price":266.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.2ZP.jpg?v=1716943528"},{"product_id":"hs2cas-4zp","title":"HiSPEC HS2CAS\/4ZP Mains 2CAS Four Zone Panel","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/4ZP Mains 2CAS Four Zone Panel\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Zone, 4 Zone \u0026amp; 8 Zone available\u003c\/li\u003e\n\u003cli\u003eEach device is uniquely addressable\u003c\/li\u003e\n\u003cli\u003eCan be wired as radial loop\u003c\/li\u003e\n\u003cli\u003e15 Devices per zone\u003c\/li\u003e\n\u003cli\u003eSeparate sounder circuit not required\u003c\/li\u003e\n\u003cli\u003e2048 Event history log\u003c\/li\u003e\n\u003cli\u003eSurface mountable and recessed mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply Voltage: 230v ac 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 29v dc nominal (19-30v)\u003c\/li\u003e\n\u003cli\u003eLoop Sounder Circuit Supply: 2x Conventional, 28v nominal, 150mA (20-30v dc)\u003c\/li\u003e\n\u003cli\u003eFault Relay: 1xSELV@1A (normally energised)\u003c\/li\u003e\n\u003cli\u003eFire Relay: 1xSELV@1A\u003c\/li\u003e\n\u003cli\u003eDetection Circuits: 8 Radial Circuits (Max), 4 Loop Circuits (Max)\u003c\/li\u003e\n\u003cli\u003eLoop Sounder Circuit: 80 Sounder (Max)\u003c\/li\u003e\n\u003cli\u003eRepeater Panel Connection: RS485\u003c\/li\u003e\n\u003cli\u003eApproved to: BS5839-1 \u0026amp; 6\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54-2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/4ZP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/design\/button_-data-sheet.png?v=202d1171b08f05d602813a65d49ae269\" title=\"Data Sheet for HS2CAS\/4ZP\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041202274,"sku":"HS2CAS\/4ZP","price":298.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.4ZP.jpg?v=1716943530"},{"product_id":"hs2cas-8zp","title":"HiSPEC HS2CAS\/8ZP Mains 2CAS Eight Zone Panel","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/8ZP Mains 2CAS Eight Zone Panel\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Zone, 4 Zone \u0026amp; 8 Zone available\u003c\/li\u003e\n\u003cli\u003eEach device is uniquely addressable\u003c\/li\u003e\n\u003cli\u003eCan be wired as radial loop\u003c\/li\u003e\n\u003cli\u003e15 Devices per zone\u003c\/li\u003e\n\u003cli\u003eSeparate sounder circuit not required\u003c\/li\u003e\n\u003cli\u003e2048 Event history log\u003c\/li\u003e\n\u003cli\u003eSurface mountable and recessed mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply Voltage: 230v ac 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eSystem Voltage: 29v dc nominal (19-30v)\u003c\/li\u003e\n\u003cli\u003eLoop Sounder Circuit Supply: 2x Conventional, 28v nominal, 150mA (20-30v dc)\u003c\/li\u003e\n\u003cli\u003eFault Relay: 1xSELV@1A (normally energised)\u003c\/li\u003e\n\u003cli\u003eFire Relay: 1xSELV@1A\u003c\/li\u003e\n\u003cli\u003eDetection Circuits: 8 Radial Circuits (Max), 4 Loop Circuits (Max)\u003c\/li\u003e\n\u003cli\u003eLoop Sounder Circuit: 80 Sounder (Max)\u003c\/li\u003e\n\u003cli\u003eRepeater Panel Connection: RS485\u003c\/li\u003e\n\u003cli\u003eApproved to: BS5839-1 \u0026amp; 6\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54-2 \u0026amp; 4\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/8ZP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.2zp-hs2cas.4zp-hs2cas.82p-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/8ZP\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041235042,"sku":"HS2CAS\/8ZP","price":386.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.8ZP.jpg?v=1716943530"},{"product_id":"hs2cas-he-90f","title":"HiSPEC HS2CAS\/HE\/90F 2CAS 90' Fixed Heat Detector","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/HE\/90F 2CAS 90' Fixed Heat Detector\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with Sounder\/ Flasher Base\u003c\/li\u003e\n\u003cli\u003eSoft Addressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eRemove LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Rate of Rise (Thermistor A1R)\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: Rate of Rise\/ Fixed Heat Trigger @57°C\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 152g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 308g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 5\u003c\/li\u003e\n\u003cli\u003eIncluded: Head Only\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/HE\/90F\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041267810,"sku":"HS2CAS\/HE\/90F","price":30.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/2cas-90-c-fixed-temp-heat-detector-head-only-with-base-with-sounder-flasher-base-2130-p.jpg?v=1716943531"},{"product_id":"hs2cas-he","title":"HiSPEC HS2CAS\/HE 2CAS Heat Detector","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/HE 2CAS Heat Detector\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with Sounder\/ Flasher Base\u003c\/li\u003e\n\u003cli\u003eSoft Addressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eRemove LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Rate of Rise (Thermistor A1R)\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: Rate of Rise\/ Fixed Heat Trigger @57°C\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 152g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 308g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 5\u003c\/li\u003e\n\u003cli\u003eIncluded: Head Only\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/HE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/design\/button_-data-sheet.png?v=202d1171b08f05d602813a65d49ae269\" title=\"Data Sheet for HS2CAS\/HE\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041333346,"sku":"HS2CAS\/HE","price":30.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.HE.jpg?v=1716943535"},{"product_id":"hs2cas-he-sb60f","title":"HiSPEC HS2CAS\/HE\/SB60F 2CAS 60' Fixed Heat Detector c\/w Sounder \u0026 Beacon","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/HE\/SB60F 2CAS 60' Fixed Heat Detector c\/w Sounder \u0026amp; Beacon\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with Sounder\/ Flasher Base\u003c\/li\u003e\n\u003cli\u003eSoft Addressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eRemove LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Rate of Rise (Thermistor A1R)\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: Rate of Rise\/ Fixed Heat Trigger @57°C\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eCoverage: 50m²\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 152g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 308g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 5\u003c\/li\u003e\n\u003cli\u003eIncluded: Head, Sounder \u0026amp; Flasher Base\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/HE\/SB60F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/design\/button_-data-sheet.png?v=202d1171b08f05d602813a65d49ae269\" title=\"Data Sheet for HS2CAS\/HE\/SB60F\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041366114,"sku":"HS2CAS\/HE\/SB60F","price":42.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/2cas-60-c-fixed-temp-heat-detector-head-only-with-base-with-sounder-flasher-base-2128-p_d5298fca-31fd-4fb9-ae97-4a25cebf5aa0.jpg?v=1716943535"},{"product_id":"hs2cas-io","title":"HiSPEC HS2CAS\/IO 2CAS Input\/Output Module 230V","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/IO 2CAS Input\/Output Module 230V\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast activation response\u003c\/li\u003e\n\u003cli\u003eLoop powered\u003c\/li\u003e\n\u003cli\u003e5 Status LEDs\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003cli\u003eFeatures an integral short circuit loop isolator\u003c\/li\u003e\n\u003cli\u003eSingle mains rated relay contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage: 17 - 30v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 2.7mA\u003c\/li\u003e\n\u003cli\u003eAlarm Current: 6.1mA\u003c\/li\u003e\n\u003cli\u003eFault Current: 6.5mA\u003c\/li\u003e\n\u003cli\u003eOutput Current: 6.1mA (9.7mA with input in alarm)\u003c\/li\u003e\n\u003cli\u003eOutput Relay Rating: 5A 250VAC\/30V DC\u003c\/li\u003e\n\u003cli\u003eCable Size (Max): 2.5mm²\u003c\/li\u003e\n\u003cli\u003eProduct Case Material: ABS\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ + 50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/IO\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041398882,"sku":"HS2CAS\/IO","price":56.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.IO.jpg?v=1716943535"},{"product_id":"hs2cas-he-sb90f","title":"HiSPEC HS2CAS\/HE\/SB90F 2CAS 90' Fixed Heat Detector c\/w Sounder \u0026 Beacon","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/HE\/SB90F 2CAS 90' Fixed Heat Detector c\/w Sounder \u0026amp; Beacon\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable with Sounder\/ Flasher Base\u003c\/li\u003e\n\u003cli\u003eSoft Addressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eRemove LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Rate of Rise (Thermistor A1R)\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: Rate of Rise\/ Fixed Heat Trigger @57°C\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eCoverage: 50m²\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 152g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 308g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 5\u003c\/li\u003e\n\u003cli\u003eIncluded: Head, Sounder \u0026amp; Flasher Base\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/HE\/SB90F\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041431650,"sku":"HS2CAS\/HE\/SB90F","price":42.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/2cas-90-c-fixed-temp-heat-detector-head-only-with-base-with-sounder-flasher-base-2130-p_0dd5e2e6-3932-42f4-9326-71e0f0e86663.jpg?v=1716943536"},{"product_id":"hs2cas-mcp","title":"HiSPEC HS2CAS\/MCP 2CAS Manual Call Point","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/MCP 2CAS Manual Call Point\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupplied with clear plastic protective cover\u003c\/li\u003e\n\u003cli\u003eSupplied with reset key\u003c\/li\u003e\n\u003cli\u003eHigh impact ABS glass fibre material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage: 17 - 28 VDC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 600? (Max)\u003c\/li\u003e\n\u003cli\u003eElement Type: Resettable\u003c\/li\u003e\n\u003cli\u003eAlarm Current: 2.5MA (Max)\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -20°C ~ +60°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-Condensing\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP32 (IP67 Available)\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54-11\u003c\/li\u003e\n\u003cli\u003eWeight (IP32): 150g\u003c\/li\u003e\n\u003cli\u003eWeight (IP67): 250g\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/MCP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.mcp-hs2cas.mcp-ip67-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/MCP\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041497186,"sku":"HS2CAS\/MCP","price":29.82,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.MCP.jpg?v=1716943540"},{"product_id":"hs2cas-pe","title":"HiSPEC HS2CAS\/PE 2CAS Optical Smoke Detector","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/PE 2CAS Optical Smoke Detector\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSounder \u0026amp; Beacon Base available\u003c\/li\u003e\n\u003cli\u003eLow Profile Design\u003c\/li\u003e\n\u003cli\u003eAnti tamper capability\u003c\/li\u003e\n\u003cli\u003eAddressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eRemote LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetection Type: Optical\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 500 ?A\u003c\/li\u003e\n\u003cli\u003eAlarm Current @24v DC: 5mA\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -10°C ~ +50°C (min cont. 0°)\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-condensing\u003c\/li\u003e\n\u003cli\u003eAlarm Condition: 0.09 dB\/m - 0.11 dB\/m\u003c\/li\u003e\n\u003cli\u003eCoverage: 100m²\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP43\u003c\/li\u003e\n\u003cli\u003eWeight (Head Only): 164g\u003c\/li\u003e\n\u003cli\u003eWeight (W\/Sounder Flasher Base): 318g\u003c\/li\u003e\n\u003cli\u003eApproved to: LPCB\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 7\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/PE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.pe.sb-hs2cas.pe-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/PE\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041529954,"sku":"HS2CAS\/PE","price":30.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.PE.jpg?v=1716943540"},{"product_id":"hs2cas-mcp-ip67","title":"HiSPEC HS2CAS\/MCP-IP67 2CAS Manual Call Point IP67","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/MCP-IP67 2CAS Manual Call Point IP67\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupplied with clear plastic protective cover\u003c\/li\u003e\n\u003cli\u003eSupplied with reset key\u003c\/li\u003e\n\u003cli\u003eHigh impact ABS glass fibre material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage: 17 - 28 VDC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 600? (Max)\u003c\/li\u003e\n\u003cli\u003eElement Type: Resettable\u003c\/li\u003e\n\u003cli\u003eAlarm Current: 2.5MA (Max)\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -20°C ~ +60°C\u003c\/li\u003e\n\u003cli\u003eMax Humidity: 95% RH Non-Condensing\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP32 (IP67 Available)\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54-11\u003c\/li\u003e\n\u003cli\u003eWeight (IP32): 150g\u003c\/li\u003e\n\u003cli\u003eWeight (IP67): 250g\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/MCP-IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.mcp-hs2cas.mcp-ip67-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/MCP-IP67\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041562722,"sku":"HS2CAS\/MCP-IP67","price":70.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/2cas-manual-call-point-ip67-2135-p.jpg?v=1716943540"},{"product_id":"hs2cas-s-ip65","title":"HiSPEC HS2CAS\/S-IP65 2CAS Weatherproof Sounder IP65","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/S-IP65 2CAS Weatherproof Sounder IP65\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 Tone patterns selectable\u003c\/li\u003e\n\u003cli\u003eHoused in UL VO flame retardant ABS\u003c\/li\u003e\n\u003cli\u003e3 x 20mm knock outs (2 top, 1 bottom)\u003c\/li\u003e\n\u003cli\u003eAddressable via dip-switches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage: 17 - 28v DC\u003c\/li\u003e\n\u003cli\u003eQuiescent Current: 1.5mA\u003c\/li\u003e\n\u003cli\u003eAlarm Current: 5.4mA\u003c\/li\u003e\n\u003cli\u003eSounder Type: B\u003c\/li\u003e\n\u003cli\u003eAmbient Op Temp: -25°C ~ + 70°C\u003c\/li\u003e\n\u003cli\u003eSound Output @ 1m: 96.9dB +\/- 3dB\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP65\u003c\/li\u003e\n\u003cli\u003eDesigned to: EN54 - 3 Part B\u003c\/li\u003e\n\u003cli\u003eProduct Code: HS2CAS\/S-IP65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.s-ip65-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/S-IP65\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041595490,"sku":"HS2CAS\/S-IP65","price":48.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/HS2CAS.S-IP67.jpg?v=1716943541"},{"product_id":"hs2cas-pe-sb","title":"HiSPEC HS2CAS\/PE\/SB 2CAS Optical Smoke Detector c\/w Sounder \u0026 Beacon","description":"\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong\u003eHiSPEC HS2CAS\/PE\/SB 2CAS Optical Smoke Detector c\/w Sounder \u0026amp; Beacon\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSounder \u0026amp; Beacon Base available\u003c\/li\u003e\n\u003cli\u003eLow Profile Design\u003c\/li\u003e\n\u003cli\u003eAnti tamper capability\u003c\/li\u003e\n\u003cli\u003eAddressable via dip-switches\u003c\/li\u003e\n\u003cli\u003eRemote LED Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Code: HS2CAS\/PE\/SB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/files.ekmcdn.com\/8f4554\/resources\/other\/hs2cas.pe.sb-hs2cas.pe-spec-sheet.pdf\" title=\"Data Sheet for HS2CAS\/PE\/SB\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick Here for Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HiSPEC","offers":[{"title":"Default Title","offer_id":41179041759330,"sku":"HS2CAS\/PE\/SB","price":42.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0582\/1693\/9618\/files\/2cas-optical-smoke-detector-2136-phs2cas.pe.sb.jpg?v=1716943545"}],"url":"https:\/\/b2belectrical.com\/collections\/hispec-2cas-commercial-fire-alarm-system.oembed","provider":"B2Belectrical.com","version":"1.0","type":"link"}